SGE · Smart Gateway Enclosure

Product overview

SGE

Video, sensors and field devices in one edge platform.

The Smart Gateway Enclosure combines I/O, storage and communication options. A two-main-board configuration supports redundancy through mutual status monitoring.

Edited product photograph from supplied materials · configuration example
01

Video and sensor integration

Configure recording, AI analysis, environmental sensors and field device connections.

02

Redundant main boards

Two installed main boards monitor each other to implement fault tolerance.

03

Modular system expansion

Match system boards and I/O to the site, with SDK support or separately scoped development.

Operational features

  • Alarm I/O · RS-232 · RS-485
  • M.2 × 2 / SATA × 2 configuration
  • Optional Wi-Fi 6 and LTE / 5G

Industrial sites combining video, environmental sensors and device control

1 Gbps Ethernet480 fps recording / 4K 60 fps decodingTwo-main-board redundancy configuration

Confirm failover and recovery scope for the configuration and operating conditions. No zero-downtime, lossless-data or availability guarantee is stated. Features and screens depend on product configuration, connected devices and installed software.

SGE
The two populated cards in the centre of the SGE chassis: the left card is labelled main board 1 and the right card main board 2.
  • Main board 1 · Left card
  • Main board 2 · Right card

The two marked cards are the main boards that form the redundant configuration. They monitor each other’s status to provide fault tolerance.

Example SGE chassis configuration, edited from the supplied product photograph. Installed modules and communications options vary by configuration.

From site information to monitoring and connected equipment

Illustrative diagram

Site inputs

  • CCTV video
  • Environmental sensors

SGEIntegrated edge platform

  • Video recording
  • On-site AI analysis
  • Sensor collection

Monitoring and site integration

  • Monitoring display
  • Event alerts
  • Connected equipment

An example of connections to external equipment. Wi-Fi 6 and LTE/5G are optional. Confirm AI features, sensor and control integrations, I/O and storage for the intended environment.

FAULT TOLERANCE

Redundant main boards

Redundancy is a core element of the SGE design. The enclosure accepts two main boards, which monitor each other’s operating status to implement fault tolerance.

Identify both main boards in the product photograph
The two pictured cards are main boards
Of the two cards in the centre of the photograph, the left card is main board 1 and the right card is main board 2. Their numbers match the boards in the diagram above.
Mutual monitoring
The two main boards check each other’s operating status.
Fault tolerance
Each board detects a fault in the other, so the design can respond to the failure of a single board.

Applies to configurations fitted with two main boards. Confirm which functions switch over after a fault, and the scope of recovery, for the board and software configuration and operating conditions.

SYSTEM BOARDS

System boards configured for the site

Combine the main control board and backplane with I/O and storage boards. Select the I/O cards needed for the installation, with custom board development available for project requirements.

Product photograph of the SGE main control board

CONTROL

Main control board

The board provides SGE control. In a configuration with two main boards, the boards monitor each other to implement redundancy.

Control · redundant configuration

SGE backplane board with a row of card slots

CONNECTION

Backplane board

The base board accommodates and connects the system boards, bringing control, I/O and storage boards into one assembly.

Board mounting · connection

SGE I/O board for alarm and serial connections

INTERFACES

I/O board

Provides alarm inputs and outputs, RS-232 and RS-485 connections, and status LEDs.

Alarm In/Out · RS-232 · RS-485 · Status LED

SGE SATA board for M.2 and SATA storage expansion

STORAGE

SATA storage board

An expansion board for M.2 and SATA storage devices, providing the connections for the required storage configuration.

M.2 × 2 · SATA × 2

Example SGE assembly with multiple system boards installed on a backplane
Example board assembly

MODULAR CONFIGURATION

Combine selected cards into one system

This example shows multiple system boards installed on the backplane. Select the I/O cards needed to configure connections and system functions for the installation.

Custom board development

Partners can develop their own boards with SDK support or commission I/O board development for the required functions.

SDK support · commissioned I/O development

Images are edited product photographs from the company brief. Confirm the board configuration and supported functions for the project requirements.

SGE (Smart Gateway Enclosure) is an integrated edge platform for combining CCTV recording, on-device AI analysis, environmental sensing and system control in one hardware platform. It connects cameras, sensors and communication devices with the recording, analysis and alerts required at the site.

Connect video, sensors and site equipment

  • Video: combine CCTV recording with WNDR-based video delivery and on-device AI analysis.
  • Sensors: collect environmental measurements and equipment status for monitoring.
  • Integration: connect analysis results and sensor events to monitoring displays, alerts and actions on connected site equipment.

Configure AI functions for the application, such as licence plate recognition, object detection and abnormal-behaviour analysis. Available functions and integrations depend on the selected hardware, models, sensors and control equipment.

A modular configuration for the required functions

Combine controller boards, I/O boards and storage expansion for the installation. Modular options include main and secondary controllers for redundancy, SATA and M.2 storage expansion, and partner-developed boards. The platform supports Linux- or Android-based configurations and SDK-assisted integration development.

Redundant main boards and fault tolerance

Redundancy is a core element of the SGE design. The enclosure accepts two main boards, which monitor each other’s operating status to implement fault tolerance.

  • Two main boards: install two main boards in one enclosure.
  • Mutual monitoring: the two main boards check each other’s operating status.
  • Fault tolerance: each board detects a fault in the other, so the design can respond to the failure of a single board.

Applies to configurations fitted with two main boards. Confirm which functions switch over after a fault, and the scope of recovery, for the board and software configuration and operating conditions.

Applications

  • Smart poles: connect CCTV, emergency call buttons, environmental sensors and street-light controls.
  • Smart parking: connect parking monitoring, licence plate recognition, payment kiosks and occupancy signs.
  • Safety and environmental monitoring: use water-level or fire-detection sensors to monitor site conditions and trigger event notifications.
  • Smart farms, factories and buildings: configure sensor collection, video monitoring and equipment integration to suit the site.

Configuration examples from the product brief

The following configuration is described in the March 2026 product brief. Confirm supplied specifications and supported functions for the selected boards, expansion modules, software and installation conditions.

SGE configuration example
CPUQuad Core ARM Cortex-A55 @ 1.9GHz
GPUMali-G31 MP2
NPU1.2 TOPS, with expansion configurations up to 5 TOPS
Memory2GB LPDDR4-3200
Built-in storage16GB eMMC
Storage expansionSATA / M.2 slots
Display outputHDMI 2.1 × 1, 4K output
Camera configuration example16-channel CCTV
Video encodingH.265 1080P @ 60fps / H.264 1080P @ 30fps
Recording480fps recording
Video decoding4K 60fps decoding
Playback displayUp to 16 simultaneous tiles
I/OUSB 2.0 × 2, RS-232, RS-485
Alarm connections4 TTL inputs, 1 output
Network configurations1Gbps Ethernet; Wi-Fi 6 (optional), LTE / 5G (optional)
Power+24V DC (Typical)

Plan the deployment around the site

Identify the required cameras, sensors, network and controlled equipment first, then define the board configuration and software integration. The deployment process covers requirements analysis, custom development, installation and operational support. Confirm video latency, analysis performance and fault-handling behaviour for the actual configuration and operating conditions.

SGE technology and applications · Enquire about SGE