WAVERSA SYSTEMS

WServer AI User Guide

Follow the workflow from connecting a camera to configuring AI, drawing detection areas, reviewing events and finding recordings. Check live video first, connect the required AI models, then configure areas and detection conditions. Review both events and recordings to check the result. Available menus and models depend on the device, account permissions and service entitlement.

Connect and log in

This guide covers features as of 24 October 2026. The device display and connected interface use the same menu names and workflow. Channel capacity and available AI depend on the supplied model. An 8-channel model offers up to a 9-tile layout; an empty tile is not an additional camera.

Open the device address supplied by your installer. HTTPS requires a trusted certificate for that address. The website language selector is separate from the device interface, which currently offers Korean and English.

On a newly initialized device, log in as admin with a blank password, then set a new password of at least 4 characters. Use the existing password on a device already in service.

  1. Select Log in and enter the ID and password issued to you.
  2. On a shared computer, leave Remember ID and Keep me logged in unselected. Keeping a login does not provide an unlimited session.
  3. If prompted to change the password, enter the current password, new password and confirmation, save, then log in with the new credentials.
  4. Open Live Monitoring / Playback and check the camera list and video before changing camera or AI settings.
  5. Log out when finished. If the login screen keeps reappearing, check whether the same account is being used on other devices and review its session status.
Connect and log in
RoleAvailable tasks
AdministratorManage cameras, AI, system settings, PTZ, I/O, audio, USB backup, event acknowledgement and user accounts.
UserView live video, playback, searches, events and disk status, and change your own account. Missing configuration buttons may reflect your account permissions.

Check live video

The Live view under Live Monitoring / Playback is the starting point for checking camera connections and AI results. Changing the viewing layout does not change recording settings.

Enabling flame or smoke detection adds a natural-hazard badge beside the AI badge. It indicates feature configuration, not an actual alarm. The top RSI gauge helps check correction processing; it is not a detection-accuracy score.

  1. Select Live and a layout offered by the device. The 8-channel model provides 1-, 4- and 9-tile layouts.
  2. Use the camera list or previous and next channel buttons to display the required video. Use one tile to inspect a channel in detail.
  3. Open the tile’s ⋯ menu to inspect stream information. If AI results are missing, first check AI overlay visibility.
  4. Open PTZ control only when you need to move a supported camera. Hold a direction or zoom button to move the camera; release it to stop.
  5. To review an earlier scene, use Play recent recording in the ⋯ menu. It opens recording from approximately 30 seconds earlier. Select Live to resume current monitoring.
Read analysis overlaysScreen

Actual product video renderer with an example scene and detection data. People, vehicles, paths, counts, confidence and intrusion states are not real detections.

  1. Red zone and Intrusion labelRead the intrusion state of a named zone. This label is not a button.
  2. Object boxes and pathsReview object positions and tracked people’s paths alongside the image.
  3. IN / OUTCumulative barrier / people counts. The numbers in this example are synthetic.

Read analysis overlays

Example intrusion zone, object, path and IN/OUT overlays

Actual product video renderer with an example scene and detection data. People, vehicles, paths, counts, confidence and intrusion states are not real detections.

Connect cameras and configure recording

Under Cameras, open Settings for the required channel and confirm the channel in the dialog title. Prepare the camera address, account and connection type supplied by the installer. An empty camera name displays the channel number.

  1. Enter a camera name and enable the channel.
  2. Choose the actual connection type: ONVIF, Waversa or RTSP. For ONVIF or Waversa, select a discovery result or enter the address. For RTSP, enter the stream URL provided by the camera.
  3. For a new connection, enter the camera user and password. Leave both fields blank to retain the saved account.
  4. Open Main/Sub stream settings in camera settings and choose codec, resolution, FPS and GOP within the camera-supported ranges, then apply. The recommended substream is H.265, VGA-class resolution and 15 FPS, where supported. Recheck the reported values after applying. Single-camera view prioritizes the main stream; reception and decoding conditions may require the substream.
  5. Choose Continuous, Schedule or Event recording and set the times as described below.
  6. For PTZ, select ONVIF or RS-485 Pelco-D. For Pelco-D, match the I/O port role, communication speed and camera address to the connected equipment.
  7. Select Save and wait for the device to finish applying the settings. After the saved message, check live video and reopen Settings to confirm the recording mode. If an error remains, correct the indicated fields and save again.
Connect cameras and configure recording
Recording modeConfigure and verify
ContinuousSelect continuous recording while the channel is enabled. Confirm actual storage through disk status and recording playback.
ScheduleClick or drag one-hour cells for each day. Selecting a day name toggles that entire day. Finish with Save in the camera dialog.
EventEnter 0–30 seconds before and 0–600 seconds after an event. Recording covers motion, AI detection and alarm events; it does not retain every moment as continuous recording does.
Camera registration and recording modeScreen

Actual product UI showing example camera settings. camera.example.invalid is an example address; account fields are empty.

  1. Camera name and Use this channelSet the display name and whether the channel is enabled. Disabling it stops its video, recording and analysis.
  2. Recording modeChoose continuous, weekly schedule or event recording, with pre- and post-event time where applicable.
  3. Camera type and SaveEnter the source and required connection information, then save to register it.

Camera registration and recording mode

Actual WServer camera name, recording mode and video-source settings

Actual product UI showing example camera settings. camera.example.invalid is an example address; account fields are empty.

Discover, register and delete cameras

In Camera management, open Camera discovery and registration, search, then select cameras. Assign a name and channel, and use a suggested known account or a previously used username. Apply one username and password to the selected cameras when they share credentials. Replacement confirmation is required only for channels that already contain a camera.

Use Delete camera beside Camera discovery and registration to select channels to clear. Registration details and AI, motion and recording settings are reset; existing recordings are retained. Register the cleared channel again through discovery or its settings.

Main/sub streams and GOP

Open Main/Sub stream settings in camera settings and choose codec, resolution, FPS and GOP within the camera-supported ranges, then apply. The recommended substream is H.265, VGA-class resolution and 15 FPS, where supported. Recheck the reported values after applying. Single-camera view prioritizes the main stream; reception and decoding conditions may require the substream.

Connect AI models and verify execution

Open AI settings for the channel under Cameras. A connection between cards is an actual analysis setting. Check both whether a card is connected and whether it is running.

AI card connections and optionsScreen

Actual product web UI with example data. Models, connections, running states and counts are illustrative; available features depend on the device.

  1. Person appearance cardSelect a card to view its analysis options under Details.
  2. Highlighted destination cardSelect the source card, then a highlighted destination. Connection changes are saved automatically.
  3. × on the left of a cardDisconnect the input to that card. On a device, the change is saved automatically.

AI card connections and options

WServer AI card connections and person appearance options

Actual product web UI with example data. Models, connections, running states and counts are illustrative; available features depend on the device.

RSI settings by cardScreen

Current product UI with public example data. No operational camera footage or accounts are included.

RSI settings by card

RSI settings by card

Current product UI with public example data. No operational camera footage or accounts are included.

Example: connect area intrusion detection

Use this sequence when the models are available on the device. Follow the parent and child connections offered by the screen rather than substituting an unrelated card for a missing model.

  1. Confirm the camera channel in the dialog title.
  2. Select Camera video, then select Person detection from the available connection candidates.
  3. Select the connected Person detection card as the source and connect Person appearance. Continue with Person appearance → Object tracking management → Area intrusion detection.
  4. Check the connection line and status at each step. A parent can feed multiple analyses, but only the offered connection candidates can be selected.
  5. Select Area intrusion detection to open its detailed settings below. If prompted to define an area, continue with Add zone in the next section.
  6. To disconnect a card, select × on its left. Clear selection only clears the selected source card; it does not delete a connection.

Read connection and runtime status

Read the included, subscription or purchase badge together with the runtime status. A connection line alone does not mean that entitlement and execution requirements are satisfied.

Read connection and runtime status
StatusWhat to check
RunningThe camera, required parent models and execution conditions are ready. Check actual detection results in live video and events.
OffCheck whether the model is connected and whether any required detection targets are selected.
Not subscribed · InactiveUse Subscribe or Manage on the card to review entitlement for the model and channel. Connecting it alone does not enable execution.
Upstream model not subscribed · InactiveCheck entitlement along the parent path first. Subscribing only to the downstream model may not resolve it.
Subscribed channel capacity exceededCheck other channels using the same model and the capacity of its parent models. A saved connection can still be blocked from running.
Waiting / Waiting for NPUCheck whether the camera is enabled and connected, its parents, and the device analysis status. A saved connection is not proof that analysis is running.
Save error / Waiting for device responseCheck connectivity and administrator access, then inspect the current card state again. Do not assume the last value you clicked was saved.

Detailed options and when they apply

Select a connected card to display its detailed settings below. Available options and execution depend on the installed models.

Detailed options and when they apply
SettingInput and application
Object detectionChoose the object classes. Selection changes save automatically. If needed, draw and save an analysis region separately.
Person appearanceChoose available options such as upper clothing, lower clothing, hat, gender and age. If the screen reports that a model is unavailable, do not expect results for that analysis.
Object tracking managementEnter an integer from 1 to 1440 minutes for Object validity period and select Save. This retains object management information after the last detection; it is not a recording retention period.
Region, barrier and loitering dialogsEdit inside the dialog and select Save. Their application differs from automatically saved card connections.

RSI correction learning by card

RSI supplements baseline AI detection with learning from site video. Only supported cards show an RSI button. Enable RSI on the required card for each channel and apply. Subscription scope is device-wide, but correction applies only to channels and cards with RSI enabled. A single learning camera is no longer selected in system settings.

Flame and smoke use separate sensitivity for learning candidates and normal detection. A sensitive learning candidate is not automatically an alarm. After learning, check both real flame/smoke scenes and normal scenes at operating sensitivity. In baseline/RSI comparison display, corrected results carry the RSI label. The dot animation indicates the RSI option, not detection accuracy or completed learning.

Where the object detection card offers RSI, video clips of objects repeatedly observed at a fixed location can be collected for correction. Its support conditions differ from flame/smoke RSI; use only the functions offered on the card. After moving the camera or changing the environment, check real targets and false detections again in the new view.

On supported devices, collected video crops train a supplementary model in the background for RSI inference. This does not replace the baseline detector with a new model. Learning alone does not establish improved accuracy in every scene; compare detections and false detections at the lower operating sensitivity.

AI subscriptions and per-channel use

In the current distribution, activate a feature with its AI card subscription button without separate organization registration. Activation covers all channels on that device, while connections and ON/OFF settings remain per channel. Activating one card does not enable every other AI card. Features that depend on upstream analysis still require that analysis to be available.

Built-in AI features do not need a subscription button. Earlier distributions with a separate contract-based subscription screen follow the status shown there. AI activation and P2P remote-access registration are separate procedures.

Configure analysis regions, intrusion zones and counting

An analysis region limits where a model analyses, an intrusion zone defines where intrusion is evaluated, and a barrier is a line crossed by people. Select the required model card before opening its editor.

Intrusion detection conditionsScreen

Actual product web UI with example data. The confirmation time and zone names are examples, not a recommended detection policy.

  1. Add zoneOpen the editor for a new detection zone. Select an existing zone button to edit it.
  2. Confirmation timeSet how long the same tracked target must remain in the zone.
  3. Detect by visible foot position onlyChoose whether to evaluate only targets with a detected foot position. Changes are saved automatically.

Intrusion detection conditions

AI settings with Add zone, confirmation time and the foot-position option

Actual product web UI with example data. The confirmation time and zone names are examples, not a recommended detection policy.

Define a detection zone on the imageScreen

Actual product zone editor showing an example scene. The illustration, names and coordinates are illustrative, not a live camera image.

  1. Zone nameEnter a recognizable name, such as Restricted area.
  2. Image and numbered verticesClick the image to add points and drag the points to adjust the boundary.
  3. SaveApply the edited name and zone. Cancel leaves the current edit unapplied.

Define a detection zone on the image

Actual zone editor with polygon vertices and a zone name

Actual product zone editor showing an example scene. The illustration, names and coordinates are illustrative, not a live camera image.

Define an analysis region

Use a model that offers Analysis region, such as Object detection or Person detection. The editor background is a recent recorded frame, not live video. If there is no frame, the editor reports a blank background; check the current camera view and recording status first.

  1. Open Analysis region from the model card.
  2. Click around the boundary to add 3–16 vertices. Avoid duplicate points or crossing edges.
  3. Drag points to adjust them. Undo last point removes the final vertex. Whole picture removes the restriction and selects the entire image.
  4. Select Save. If a vertex error appears, correct the shape and save again. Select Cancel to leave it unchanged.
  5. Check the Selected region or Whole picture indicator in the detailed settings, then check live results in the intended area.

Configure area intrusion detection

First check the connected AI path and the runtime status of Area intrusion detection. An intrusion is reported when the same tracked object remains in the zone for the configured confirmation time.

  1. Select Add zone on the Area intrusion detection card. Up to four zones are available.
  2. Enter a Zone name, or leave it blank for the default. Draw 3–16 vertices on the frame and select Save.
  3. In the detailed settings, enter a Confirmation time from 0 to 600 seconds. This change saves automatically.
  4. Choose whether to enable Detect by visible foot position only. When enabled, objects without detected foot positions are not confirmed as intrusions, including scenes where feet are obscured.
  5. Open an existing zone using its name button. To remove it, select Delete zone and then Save. Cancel leaves that deletion unapplied.
  6. Check the zone name and active intrusion indication in live video, then inspect the camera and zone details in Events. Connect an output in Event Map if an alarm or speaker must operate.

Set barrier direction and check IN/OUT

  1. Connect Barrier / people counting under Object tracking management and open Edit barrier.
  2. Drag endpoints A and B into place. Crossing towards the arrow counts as IN; crossing the opposite way counts as OUT. Use Swap direction to swap them.
  3. Choose whether to show the barrier and select Save. If the line is too short, move the endpoints farther apart.
  4. Compare crossings with the live IN/OUT counters. If direction is reversed, reopen Edit barrier, reverse it and save.
  5. Use Reset counts only when the accumulated totals should start again, and wait for the pending message to clear.

Adjust loitering confirmation time

  1. Open Settings on the Loitering detection card.
  2. Enter a whole-number Detection time (seconds) from 10 to 3600.
  3. Enable cross-camera appearance linking only when evaluating that experimental feature at the site. Keep it distinct from ordinary single-camera configuration.
  4. Select Save, then check card status and events. Cancel does not apply changes made in this dialog.

Flame/smoke sensitivity and alarm count

Set sensitivity and the accumulated detection count required for an alarm in the flame and smoke cards. Flame uses a red outline and smoke a blue outline; the two may overlap. Detections of the same type in the same area are grouped and counted, and counting restarts for a new scene. The number is a detection count for that area, not a people count.

Use a fixed camera and stable framing, and check false detections under lighting changes, reflections and scenes with people. If an old box remains after a scene change or keeps expanding, record the scene, time and settings for investigation rather than accepting the result as valid. RSI and object RSI are distinct from proving a person’s identity across cameras.

Barrier people counts and period charts

Set and save the barrier line and IN/OUT directions in AI settings. Enable count and chart display in the view options to show them below the video. In period statistics, enter start/end times or use a time preset. Numbers above the bars are crossing counts; labels below identify time intervals. Current people or head counts are detections at that moment, not accumulated IN/OUT crossings.

Playback charts center on the current playback time, with earlier records on the left and later records on the right. Select a window of 15 minutes, 30 minutes, 1 hour, 6 hours or 12 hours on each side. In live view, the future side remains empty. A loading or incomplete-data notice means the totals are not yet complete.

Separate motion detection from its display

In motion settings, configure local detection, use of ONVIF camera events and live grid/region display separately. Hiding the overlay does not disable detection or event recording. Check that the camera supplies ONVIF events and test with actual movement.

Review events and open recordings

The Events tab under Events lists recent activity. To investigate a specified earlier time, use Search as described in the next section.

  1. Narrow the list with the event message search, camera and All states, Unread or Acknowledged filters. Filter changes update the displayed list.
  2. Open an event picture to inspect its time, source, type, message and acknowledgement state. If No picture appears, review the text record first.
  3. Select Play recording for a camera event to open single-channel playback approximately five seconds before the event. Playback requires a retained recording for that period.
  4. After reviewing it, an administrator can select Acknowledge and check the completed state. Merely opening or closing the event does not acknowledge it.
  5. To rule out hidden results, clear the search text and return to All cameras and All states.
Review events and open recordings
SituationWhat to check
No picture or recording will not playCheck the event camera and time, recording mode at that time, disk status and retained recording range.
Disk event storage delayedCheck storage and query again. An empty list while this warning is present does not establish that no incident occurred.
Acknowledgement failsCheck administrator access and connectivity, then reload to see the current acknowledgement state.

Search and recording playback

Choose a search typeScreen

Current product UI with public example data. No operational camera footage or accounts are included.

Choose a search type

Choose a search type

Current product UI with public example data. No operational camera footage or accounts are included.

Recent searchesScreen

Current product UI with public example data. No operational camera footage or accounts are included.

Recent searches

Recent searches

Current product UI with public example data. No operational camera footage or accounts are included.

Search person tracking eventsScreen

Current product UI with public example data. No operational camera footage or accounts are included.

Search person tracking events

Search person tracking events

Current product UI with public example data. No operational camera footage or accounts are included.

Search with step cards

Select Time, Cameras and Search type in order. Use Last hour, Last 2 hours, Last 24 hours or a custom range, then all cameras or selected channels. Search types start with People, followed by Events, Motion, AI detection and Thumbnails. Standard searches start after the remaining conditions and display method are selected. Select an earlier card to choose the subsequent conditions again.

A ring beside the last card rotates while results arrive, then changes to a completion check. Results are limited to 500; narrow the time or cameras to inspect additional records. Motion includes local and ONVIF motion events. Intervals without recordings or valid pictures are not filled with empty picture cards.

Select a person and inspect appearances

People search uses Time, Camera selection, Person selection and Movement path cards. Only person tracking events recorded while object tracking was enabled are searched. Channels with tracking disabled at recording time and older recordings without tracking information do not generate person candidates. A person detection record is different from a person tracking record.

Candidate cards show a crop of the person. Hover to inspect a larger original scene and its target rectangle. Selecting a candidate displays connected appearance cards. Selecting an appearance card passes its timestamp to playback. Returning to search retains the results and selection in a paused state.

Cross-camera RSI identity verification, automatic playback of an entire route and batch route backup are not yet complete. Do not establish identity from matching clothing colors or similar appearance alone. A card may be omitted when an exact-time picture is unavailable; no search result does not necessarily mean no recording.

Save, pin and delete recent searches

Recall conditions from Recent searches below the first Time card. A saved Last hour preset searches the hour before the time it is recalled; a manually entered date/time restores the fixed range. Pin keeps an entry at the top, Unpin releases it, and Delete removes only the saved conditions. The device display and connected interface share searches for the same device.

Playback and thumbnail channel selection

Opening playback from a standard event result retains the existing screen layout. Use play, pause and reverse play to inspect the recording. In the playback bar and preview area above it, thumbnails show date/time and the numbered camera name. Right-click there to select a channel number, or use the mouse wheel to change the preview channel.

Connect events to displays, alarms and speakers

Event Map defines which outputs operate when a source event occurs; it does not configure the detector itself. First confirm that the camera and AI are running and events are being recorded.

  1. Select a detection source grouped under its camera in Event Map.
  2. Select a screen, alarm, speaker or other available output. Check the connection line and count. The change saves automatically.
  3. While the same source is selected, clicking an already connected output removes that link. An unlink button can also remove a selected connection or all connections from the source.
  4. To connect one source to multiple outputs, select the outputs in turn. If several sources share an output, any one of those sources can trigger it.
  5. For additional integration, use Add output to configure an available server notification or installed script output with the destination and settings approved by the installer.
  6. Use an output test only after confirming the operating scope with the site operator. If saving fails, recheck which connections actually remain.

Configure I/O and voice announcements

Use I/O Settings to configure the serial ports, alarm contacts and speaker functions actually available on the device. Use electrical and communication settings confirmed by the installer.

  1. Match the serial-port role and communication settings and alarm contact types to the connected equipment, then select Save in I/O Settings.
  2. Under Speaker, select Add clip and choose a built-in sound or a WAV file up to 4 MB. Set its name and add it.
  3. Confirm the clip appears, then adjust its volume and repeat count. Connect it as an output in Event Map to play it on detection.
  4. For background music, choose a prepared folder and track, then use Play, Pause, Stop and Volume. Event alarms pause the background music before it resumes.
  5. Check the microphone destination and allow browser microphone access. Hold PTT or Talk while speaking; release it to end transmission.

Network, P2P and DDNS remote access

Administrators configure Network, P2P registration and management, and DDNS under System Settings. P2P provides a path to the device access screen from outside the local network; DDNS gives that path a memorable name. Device-account login is required with either address.

Configure the device’s local network

  1. Open Change beside Network and select Automatic (DHCP) or a static IP address.
  2. For a static address, enter the address, subnet mask, gateway and DNS supplied by the installer.
  3. Saving can change the address immediately. Prepare the new connection address and tell other operators about a possible interruption before saving.
  4. Reconnect to the new device address and check login and live video. If external services do not connect, also check the gateway, DNS and device time.

Register P2P and verify external access

  1. In System Settings, open Register / Manage beside P2P registration and management. For an already registered device, first check the connection and service-access states.
  2. For a new registration, enter the Purchasing organization number and PIN number provided by the administrator. Use the supplied HTTPS Service address under Advanced settings.
  3. Press Register and issue URL and wait for completion. Do not repeatedly submit while issuance is in progress.
  4. Check that Access URL and Device unique ID appear. Press Copy URL; if clipboard access is unavailable, manually copy the selected URL.
  5. Press Save to apply a change to the use checkbox. Turning use off changes P2P access settings; it is not a subscription-cancellation request.
  6. Open the issued URL from an external network, separate from the device’s local network, and log in with the device account. Verify live video and any required recording access.

Separate connection state from service entitlement

Separate connection state from service entitlement
Display or situationWhat to check
Not registeredObtain the organization number and PIN from the administrator, then register.
Connecting to service / Service disconnectedCheck use settings, internet access, DNS, time and the service address. Recheck the connection before repeating registration.
Connected to serviceOpen the issued URL externally, then check device login and video. This status alone does not confirm the usage period or successful access from every network.
Trial / ActiveCheck the terms currently provided. Do not assume a particular usage period or concurrent-access limit.
Waiting for approval / Payment review requiredAsk the purchasing organization to check approval and the agreement. Saving device settings or reissuing the URL does not approve access.
Suspended / Subscription expired / CanceledAsk the administrator about restoring access. A DDNS name does not bypass these restrictions.
Registration mismatch / URL issuance limit / Check settingsGive the administrator the displayed error and time of the operation. Do not delete registration or change organizations without direction.

Register, rename or release a DDNS name

DDNS opens the device’s P2P access screen through a registered name. Complete P2P registration first. Use the domain suffix shown in settings; do not enter the company website or an arbitrary server address.

  1. Open Settings beside DDNS in System Settings.
  2. Select Use an internet name and enter 3–32 lowercase letters, digits or hyphens in Name. A hyphen cannot be first or last, and two hyphens cannot occur consecutively.
  3. Press Save and wait for Registering… to change to an access address. A settings-saved notice alone does not confirm that name registration finished.
  4. Open the displayed address from an external network and log in with the device account. If the name opens but video is missing, check P2P connection, service entitlement and camera state separately.
  5. To rename the device address, enter a new name and save. Each device has one name, so give the new address to operators who used the old name.
  6. When the name is no longer needed, press Give the name back and confirm. Another device can register that name after release.
Register, rename or release a DDNS name
SituationAction
Name already in use / name not allowedChoose another name and save again. You cannot take another device’s name or a reserved name.
Register with P2P firstCheck registration and the issued URL in P2P registration and management, then recheck DDNS settings.
Registering… / server connection errorWait briefly and reopen status. If it continues to fail, check internet access, DNS and device time.
Device disabled by an administratorAsk the organization to check P2P and DDNS access. Repeatedly choosing different names does not resolve this state.

Device access port and remote display

Set the device access port in system network settings. If it changes, update the connection address and the router’s port-forwarding destination accordingly. This does not change a camera’s ONVIF or RTSP port. In WRM screen viewing, check the device display and mouse-control state, then close it when finished.

Manage accounts, time and storage

System Settings contains your account and device operating information. Regular users see only permitted items such as their own account.

  1. Open Change for Account, enter the current password and required new ID, password and confirmation, then save. Log in again with the new credentials after the account changes.
  2. Administrators can enter a user ID and a password of at least eight characters under User accounts and select Add user. Confirm the target user before resetting a password or deleting an account.
  3. Check that the time zone matches the installation and inspect time synchronisation under NTP settings. Start here if event or recording timestamps appear incorrect.
  4. Inspect disk connection, capacity, recording status and warnings. The web disk screen is for status and does not offer formatting.
  5. Choose Fill (Crop) or Whole picture (LetterBox). Use Whole picture when the edges matter, and change the interface language if required.

Back up recordings and update firmware

USB backup writes recordings to a drive attached to the device. It does not download them to the computer running the browser.

Export a recording segment to USB

  1. Attach a backup USB drive to the device and open USB backup from Monitoring or Search.
  2. Choose the start time and enter a length in minutes or hours. Check the displayed end time and selected cameras. Use Select all or Clear all to change channel selection.
  3. Select the destination in the USB list. Use Refresh USB if a new drive is missing. Recording disks are excluded as backup targets.
  4. Choose MP4 or Waversa encrypted + Windows player. For a protected Waversa backup, enter both an ID and a password of at least eight characters; leave both blank for an unprotected backup.
  5. Use Estimate size to check space, then select Start backup. Monitor progress and output size until Backup complete appears.
  6. Select Eject USB and wait for permission to remove it before unplugging. Check that the required files are present on another computer.

Unified Upgrade and OTG Upgrade

Application and system updates are supplied in one Upgrade package. Select the package for the supplied brand and channel capacity, check the connection and install. A lightweight package without AI models preserves models already installed on the device; it is not for a new device without those models. Use OTG Upgrade and its supplied instructions for initial installation or recovery.

Recording may pause during installation. Wait for final completion and reboot instructions, then reconnect and check version, cameras, recording, AI and audio. If installation fails or the connection drops, check job status and save logs; do not start multiple installers. For low storage, use the deployment tool’s cleanup rather than deleting recordings or model files manually.

Back to top